Abstract

An array of 30 plasma synthetic jet actuators (PSJAs) is deployed using a modified multichannel discharge circuit to suppress the flow separation over a straight-wing model. The lift and drag of the wing model are measured by a force balance, and the velocity fields over the suction surface are captured by a particle imaging velocimetry system. Results show that the flow separation of the straight wing originates from the middle of the model and expands towards the wingtips as the angle of attack increases. The flow separation can be suppressed effectively by the PSJAs array. The best flow control effect is achieved at a dimensionless discharge frequency of F + = 1, with the peak lift coefficient increased by 10.5% and the stall angle postponed by 2°. To further optimize the power consumption of the PSJAs, the influence of the density of PSJAs on the flow control effect is investigated. A threshold of the density exits (with the spanwise spacing of PSJAs being 0.2 times of the chord length in the current research), below which the flow control effect starts to deteriorate remarkably. In addition, for comparison purposes, a dielectric barrier discharge (DBD) plasma actuator is installed at the same location of the PSJAs. At the same power consumption, 4.9% increase of the peak lift coefficient is achieved by DBD, while that achieved by PSJAs reaches 5.6%.