Abstract

Borehole Heat Exchange System (BHES) is introduced to control car park temperature, i. e. improvement of thermal environment at a car park in the campus of Fukui university. BHES consists of a borehole and pavement, which has an asphalt layer covering 12 concrete panels installed heat exchange piping. The borehole is 70m length and comprises outer and inner pipe. Diameters of the outer and inner pipe are 90mm and 56mm, respectively.Thermal flow circulates in a closed loop connecting between the pavement and borehole to sustain ground water quality.The efficiency and performance of BHES are evaluated experimentally and theoretically from viewpoint of seasonal thermal energy storage.It is shown that BHES can suppress the rise of the pavement temperature of the park in summer and melt the snow on the same car park in winter using only geothermal heat.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.