Abstract

A new control method of a pulsewidth modulation (PWM) rectifier without measuring AC- and DC-side voltages is proposed. As information about these voltages is necessary for the controller, all required voltage values are estimated from the measured line currents and the calculated values of the input reactor voltage during switching of the rectifier circuit. The input reactor voltage can be obtained by using a differentiator that produces the derivative of the line current or by detecting the voltage induced in a secondary winding wound on the input reactor. The secondary winding creates the electric isolation between the main circuit and the controller. The proposed method is verified by experiment. This paper describes the estimation method, gives the configuration of the controller, and discusses steady-state and transient performances of the rectifier.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.