Abstract

This paper proposes a control method to balance capacitor voltages for a four-switch single-stage two phase switched reluctance motor drive with integrated power factor correction. Initial alignment process is necessary for SRM before operation. However, the phase current is unbalanced during that time, which would cause over-voltage issue on DC capacitors as split-AC structure is used. This problem also exists when the motor speed is low, as in startup of electric vehicle. Based on the unified model, an advanced control method is proposed to eliminate the voltage difference between the capacitors. This method does not require any other circuits or components. It also does not affect the performance during normal conditions. Experiments are performed to verify feasibility of the control method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.