Abstract

This letter presents the operation characteristics of the magnetic switch attributed to the input voltage and pulse frequency in the pulsed power system. The reset current control method is proposed for improving efficiency of the magnetic switch because this method will optimally controls the hysteresis loop of the magnetic switch. Also, this method controls the saturation of the magnetic core by adjusting the amount of reset current flowing in the magnetic switch when the input voltage and pulse frequency at the pulsed power system are changed. Experimental results are presented to demonstrate the effectiveness of the proposed reset current control method of the magnetic switch.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.