Abstract

In this paper, a nonlinear fault diagnosis scheme is established for the hot strip mill process (HSMP). In HSMP, the faults affecting quality index are denoted as quality-related faults, which should be taken care as soon as possible. Projection to latent structures (PLS) is a basic model for quality-related fault detection in linear processes. In the presented work, a total kernel PLS (T-KPLS) model is utilized for modeling and monitoring HSMP, which is a typical nonlinear process. However, diagnosis tools have not been developed aiming at the nonlinear case based on T-KPLS model. Motivated by the successful use of contribution plot for the linear case, a contribution rate plot is proposed to extend contribution plots to the nonlinear case. In the end of this paper, the proposed method is applied to the hot strip mill process effectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.