Abstract

AbstractAdjacent box-girder bridges have become a popular choice as they can be constructed quickly, easily, and economically. In spite of their good performance during many years of service, one major problem has been recurrent longitudinal cracking of the grout material in the shear key. A combination of shear keys and transverse posttensioning (TPT) ties in such kind of bridges is typically used to connect the bridge girders together so that they would behave as a single integrated unit. However, information regarding the contribution of the TPT tie bars on load transfer between adjacent box girders is limited. In this study, a single-span precast prestressed concrete adjacent box-girder bridge was instrumented and monitored to study the effect of TPT tie bars on load transfer mechanism and overall bridge behavior under static and dynamic truck loads. Two sets of instruments were installed in the girders and tie bars during and after the construction of the bridge. A good correlation was achieved betwe...