Abstract
BackgroundThis study aimed to assess, by rapid tests, the immune status against COVID-19 among Healthcare Workers (HCW) with history of symptoms, and for whom SARS-CoV-2 detection was either not documented or negative.MethodsWhole blood by finger prick and serum samples were taken from HCW for use with 2 rapid lateral flow tests and an automated immunoassay.ResultsSeventy-two HCWs were included, median duration between symptoms onset and serology sampling was 68 days. Anti-SARS-CoV-2 antibodies were detected by rapid test in 11 HCW (15.3%) and confirmed in the 10 with available serum by the automated immunoassay. The frequency of ageusia or anosmia was higher in participants with SARS-CoV-2 antibodies (P = 0.0006 and P = 0.029, respectively).ConclusionsThis study, among symptomatic HCW during the first wave in France, showed that 15% had IgG anti-SARS-CoV-2, a higher seroprevalence than in the general population. Rapid lateral flow tests were highly concordant with automated immunoassay.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.