Abstract

The aim of the present study was to differentiate acute rejection, chronic rejection, and tacrolimus nephrotoxicity with color and power Doppler imaging of renal transplants. One hundred examinations were obtained from 45 patients. Pulsatility and resistive indices were calculated from color Doppler images. The grade of renal vascularization was quantified using computer-assisted pixel analysis in a rectangular region-of-interest. The percentage of vessel-covered renal parenchyma (POV) was calculated using a histogram that discriminated renal vessels from renal parenchyma via power Doppler images. Furthermore, the distance from the most peripherally located vessels to the renal capsule (PVD) was measured. A reduced POV ± 55 % proved to be the best discriminator when chronic rejection was suspected (sensitivity 79 %, specificity 87 %). Tacrolimus nephrotoxicity showed not only a moderate elevation of the Doppler signal but also an increased PVD±3.9 mm and a normal POV. We conclude that the evaluation of renal vessels by power Doppler images improves diagnostic accuracy for patients with renal allografts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.