Abstract

ObjectivesThe main objective of this study was to test the feasibility of measuring minimum audible angle in headphones with different reference positions in the horizontal plane, and comparing different types of pre-recorded head-related transfer functions. The secondary objective was to assess spatial discrimination performance in simulated unilateral hearing loss by measuring the minimum audible angle under monaural conditions using headphones. Materials and methodsMinimum audible angle was assessed in 27 normal-hearing subjects, to test their spatial discrimination abilities, using 4 datasets of pre-recorded head-related transfer functions: 2 recorded on mannequins (KU100, KEMAR), and 2 individualized head-related transfer function datasets (TBM, PBM). Performance was evaluated at 3 reference positions (0°, 50° and 180°) in 1 binaural and 2 monaural conditions. ResultsKU100 generated minimum audible angle values smaller than KEMAR in frontal and lateral position P<0.005), with a suggestive difference (P<0.05) compared to TBM and PBM in the frontal and lateral planes. Comparison between binaural and monaural conditions showed significant differences in frontal position for MON-c (contralateral) and MON-i (ipsilateral) (P<0.001), in lateral position for MON-c only (P<0.001) and in posterior position for MON-c and MON-i (P<0.001). ConclusionThis study suggests that evaluation of spatial discrimination capacity using minimum audible angle with the KU100 head-related transfer dataset was reliable and robust.