Abstract
Contrast-Enhanced Ultrasonography (CEUS) is an imaging modality allowing perfusion quantification in targeted regions of interest of the lower extremity that has not been possible with color-flow imaging or with measurement of ankle brachial indices. We developed a protocol to quantify lower extremity muscle perfusion impairment in PAD patients in response to exercise. Thirteen patients with Rutherford Class I-III Peripheral Arterial Disease (PAD) and no prior revascularization procedures were recruited from the Baltimore Veterans Affairs Medical Center and compared with eight control patients without PAD. CEUS interrogation of the index limb gastrocnemius muscle was performed using an intravenous bolus of lipid-stabilized microsphere contrast before and after a standardized treadmill protocol. Peak perfusion (PEAK) and time to peak perfusion (TTP) were measured before and after exercise. Between and within group differences were assessed. Control subjects demonstrated a more rapid TTP (p<0.01) and an increase in peak perfusion (PEAK, p=0.02) after exercise, when compared to their baseline measures. Patients with PAD demonstrated TTP and PEAK measures equivalent to controls at baseline (p=0.39, p=0.71, respectively). However, they exhibited no significant exercise-induced changes in perfusion (TTP p=0.49 and PEAK 0.67, respectively compared to baseline). After exercise, normal subjects had significantly shorter TTP (p=0.04) and greater PEAK (p=0.02) than PAD patients. Consistent with their lack of ischemic symptoms at rest, class I to III claudicant PAD patients showed similar perfusion measures (TTP and PEAK) at rest. PAD patients, however, were unable to increase perfusion in response to exercise, whereas controls increased perfusion significantly. This corresponds with claudication and limited walking capacity observed in PAD. CEUS with bolus injection offers a convenient, objective, quantitative and visual physiologic assessment of perfusion limitation in specific muscle groups of PAD patients. This has the potential for substantial clinical and research utility.
Highlights
Contrast-Enhanced Ultrasound (CEUS) facilitates increasing the dynamic resolution of ultrasonography using a suspension of microscopic bubbles stabilized within a shell [1]
Peripheral Arterial Disease (PAD) patients, were unable to increase perfusion in response to exercise, whereas controls increased perfusion significantly. This corresponds with claudication and limited walking capacity observed in PAD
Comparing normal subjects with PAD patients at rest, no significant differences were found in either TTPB (p=0.39) or PEAKB (p=0.71)
Summary
Contrast-Enhanced Ultrasound (CEUS) facilitates increasing the dynamic resolution of ultrasonography using a suspension of microscopic bubbles stabilized within a shell [1]. CEUS is able to reveal cardiac shunts, improve ventricular luminal surface visualization, and even confirm myocardial viability when used in echocardiography [3,4]. It can determine perfusion of end-organs such as the kidney, and allows ultrasound-based distinction of hepatic tumor from normal liver parenchyma based on flow patterns [5,6,7]. We developed a protocol to quantify lower extremity muscle perfusion impairment in PAD patients in response to exercise
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.