Abstract

The objective of this article was to compare half-dose (0.05 mm/kg) gadolinium-enhanced dynamic hepatic MR imaging to standard doses (0.10 mm/kg). Eighteen patients for follow-up hepatic MR received 0.05 mm/kg of gadolinium DTPA dynamically with gradient-echo imaging. Imaging parameters were identical to a 0.10-mm/kg study; patients were imaged during multiple phases of contrast enhancement. Two readers assessed for enhancement patterns and characterization. Quantitative signal-to-noise ratios (S/N) were obtained for abdominal viscera and contrast-to-noise ratios (C/N) were obtained on up to three lesions. No significant difference for the arterial dominant phase ( P > 0.05) was found. Significant differences were found in all categories during the portal venous phase (except pancreas) and equilibrium phase (except liver). Lesion C/N ratios were not significant at any point ( P > 0.05). Sixty-two out of 64 lesions (97%) were identically characterized. Therefore, half-dose dynamic gadolinium-enhanced MR may have diagnostic value.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.