Abstract

Background: Contrast-enhanced chest computed tomography (CT) is useful for the detection and follow-up of patients with lung cancer. However, reaching balance between diagnostic image quality, radiation dose, and iodixanol dose is a cause of concern. Objectives: To investigate the clinical value of adaptive statistical iterative reconstruction (ASIR) in reducing the iodixanol content and radiation dose during contrast-enhanced chest CT scan for patients diagnosed with lung masses/nodules based on the analysis of image quality. Patients and Methods: This prospective study was conducted on 80 patients diagnosed with nodules or masses, who required contrast-enhanced chest CT scans. The experimental group (n = 40) was subjected to iohexol at a high concentration (350 mgI/L) with a tube voltage of 120 kVp and a filter back projection (FBP) reconstruction algorithm. The comparison group (n = 40) was subject to iodixanol at a lower concentration (270 mgI/L) with a tube voltage of 100 kVp and ASIR (blending ratio, 40%). The radiation dose and total iodixanol content, as well as subjective and objective evaluations of image quality, were analyzed and compared. Results: The two groups obtained non-significantly different subjective scores for five structures detected in the lung window and five structures detected in the mediastinal window, as well as the overall image (P > 0.05 for all). Both the two-group images obtained diagnosis-acceptable scores (≥ 3 points) on displays of 10 structures and overall image quality. The mean CT value of vessels (100 kVp vs. 120 kVp: 314.90 ± 23.42 vs. 308.93 ± 21.40; P > 0.05), standard deviation (13.03 ± 0.88 vs. 12.83 ± 0.90; P > 0.05), and contrast-to-noise ratio (20.77 ± 2.20 vs. 20.36 ± 1.94; P > 0.05) were not significantly different between two groups. However, the CT dose index, dose-length product, effective dose, and total iodine dose were reduced by 27.58%, 36.65%, 36.59%, and 22.86% in the 100-kVp group compared to the 120-kVp group. Conclusion: The ASIR showed great potential in reducing the radiation dose and iodine contrast dose, while maintaining good image quality and providing strong confidence for the diagnosis of lung cancer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.