Abstract
initial repair, we obtained a competent valve and also severe outflow obstruction due to systolic anterior motion (SAM) that we unsuccessfully tried to address with a conventional A2–P2 Alfieri repair. SAM persisted; hence, we removed the midline A2–P2 Alfieri stitch and placed a new edge-to-edge stitch now between the A1–P1 segments as shown in the picture. Actually, in the picture, we can see the most anterolateral of the two sets of GoreTex neochordae (in the A2 scallop close to A1) used to correct the prolapse of A2. We can also see the green pledgeted Ti-Cron sutures used for the posterior annulus plication after the quadrangular resection that mark the midline of the mitral valve. With these two references, it is clear that the newly placed Alfieri stitch was moved, as explained in the text, towards the anterolateral commissure and now holds the A1–P1 scallops together. We hope this helps clarify this technique that allowed us to preserve the mitral valve in this case of complex repair for myxomatous bileaflet prolapse.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.