Abstract

To determine the effects of atrial stretch on atrial flutter, we analyzed variations in atrial flutter cycle length (CL) caused by ventricular contraction in five dogs with artificially induced atrioventricular block. In contrast to absence of variations in CL during sustained ventricular asystole, atrial stretch by ventricular contraction consistently produced phasic variations in CL. The variations were not confined to any specific atrial sites, but depended on the time of ventricular contraction relative to atrial activation phase. The phase-response curve of the variations was closely related to that of the velocity of changes in the atrial pressure with no time lags, but not to that of the atrial pressure itself. Pharmacological denervation did not abolish the variations. Conventional electrophysiological study revealed greater changes in intra-atrial activation time by atrial stretch at a short pacing cycle length than at a longer one, suggestive of changes in repolarization by mechanical stretch. In conclusion, atrial stretch caused by ventricular contraction produces phasic variations in CL, the extent of which depends on the velocity of the mechanical stretch of atrial muscles.