Abstract

We achieve a continuous operation of a whispering gallery optical parametric oscillator by stabilizing the resonator temperature T on the mK level and simultaneously locking the pump frequency to a cavity resonance using the Pound-Drever-Hall technique. The millimeter-sized device converts several mW of a pump wave at 1040 nm wavelength to signal and idler waves around 2000 nm wavelength with more than 50% efficiency. Over 1 h, power and frequency of the signal wave vary by <±1% and by <±25 MHz, respectively. The latter can be tuned over 480 MHz without a mode hop by changing T over 120 mK. In order to prove the suitability for high-resolution spectroscopy, we scan the signal frequency across the resonance of a Fabry-Perot interferometer resolving nicely its 10 MHz linewidth.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.