Abstract

Continuous wave operation of a quantum cascade laser at λ=4.6 μm is reported above liquid nitrogen temperature. Optical powers of 15 mW at 50 K and 2 mW at 85 K are reported. The single mode spectrum is temperature tunable over 1.8 cm −1. A linewidth of 115 Mhz is measured with a Fabry–Perot on those free running devices. Gain measurements show evidence for ultra low linewidth enhancement factor α<0.1. These devices also operated in pulse mode with 20 mW peak power at 200 K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.