Abstract
Local, superficial damage was detected and localized on an 8 × 2-m concrete floor slab using a structural health monitoring system. A total of 30 piezoelectric transducers, placed in a grid, transmitted and received continuous ultrasonic waves that were measured using a lock-in amplifier. Tomography was used to create images from the measured amplitude and phase of the continuous waves between all possible transducer pairs. The location of damage induced by impact hits was visible in the resulting images. The signals could easily be detected even between the most distant transducer pairs, indicating the possibility of monitoring even very large concrete structures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.