Abstract

In this study, we aimed to determine the incidence of electrographic seizures among patients in a pediatric intensive care unit (PICU) presenting with acute encephalopathy. Risk factors and duration of continuous EEG monitoring needed to capture electrographic seizures were also assessed. Based on a NeuroICU clinical care pathway, all patients with acute encephalopathy admitted to the PICU are monitored with continuous video electroencephalogram (cVEEG) for 48 h or until the encephalopathy improves. Ninety-four consecutive patients included on the pathway over a year were identified. Mean age was 6.7 years (range 32 days-17.9 years). Data pertaining to patient clinical information and electrographic seizures, including non-convulsive seizures (NCS) and non-convulsive status epilepticus (NCSE), were extracted from a prospective database. Thirty percent (28/94) had seizures captured on cVEEG including 17 patients (18%) with NCSE. Variables associated with electrographic seizures were age <24 months and clinical seizure(s) prior to EEG placement. The first seizure captured on cVEEG occurred in the first 24 h for the majority of patients (97%). Acute brain injury and electrographic seizures were associated with worse outcome. Electrographic seizures are common in pediatric patients with acute encephalopathy. This study supports the practice of cVEEG monitoring for at least 24 h in pediatric patients with acute encephalopathy, particularly if they are less then 24 months of age and/or if a clinical event suspicious for seizure precedes the encephalopathy.