Abstract

Large diameter pipes of prestressed concrete with a length of 10–20 ft. used for water transport are made in rotating moulds. To control the thickness of these concrete pipes during production, an ultrasonic pulse-echo system mounted at the end of the feeder is used. Basically, the air gap between feeder and inner pipe wall is continuously measured, whereby deviations due to misalignment of the feeder are electronically compensated. A prototype version of the system has proved its usefulness. An accuracy of ±5% of the nominal wall thickness was obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.