Abstract
Continuous pulse oximetry (cSpO2) monitoring use outside established guidelines is common in children hospitalized with bronchiolitis. We analyzed clinicians' real-time rationale for continuous monitoring in stable children with bronchiolitis not requiring supplemental oxygen. Data for this study were collected as part a multicenter deimplementation trial for cSpO2in children hospitalized with bronchiolitis. We analyzed 371 clinician responses across 36 hospitals; 258 (70%) responses did not include a clinical reason for monitoring ("nonclinical"; e.g., respondent forgot to discontinue monitoring, did not know why the patient was monitored, or was following an order). The remaining 113 (30%) responses contained a clinical reason for monitoring ("clinical"; e.g., recently requiring oxygen, physical exam concerns, or concerns relating to patient condition or history). Strategies to reduce unnecessary monitoring should include changes in workflow to facilitate shared understanding of monitoring goals and timely discontinuation of monitoring.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.