Abstract
This work presents an experiment proposal for continuous partial discharge analysis during an automated thermal cycle experiment for hydro generator stator coils/bars. It is an innovative approach because we propose to perform partial discharges test and thermal cycle experiment simultaneously, while they are usually performed individually. We developed an automated test bench that allows performing data acquisition throughout the experiments. We decided to force different coil failures during the tests to observe any changes in the partial discharges trend. First, we changed the thermal cycle temperature limits, and this led to coil overheating before an electrical failure occurred in the insulation. Later, we applied a voltage that was higher than the rated for the coil, which led to a faster electrical failure. The partial discharges trend changed moments before the electrical fault, and the system was able to identify such change. Our preliminary results show that the continuous analysis of partial discharges trends might lead to better maintenance planning by identifying the moment when the hydro generator aging gets critical.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.