Abstract

Online monitoring of monoclonal antibody product titers throughout biologics process development and production enables rapid bioprocess decision-making and process optimization. Conventional analytical methods, including high-performance liquid chromatography and turbidimetry, typically require interfacing with an automated sampling system capable of online sampling and fractionation, which suffers from increased cost, a higher risk of failure, and a higher mechanical complexity of the system. In this study, a novel nanofluidic system for continuous direct (no sample preparation) IgG titer measurements was investigated. Tumor necrosis factor α (TNF-α), conjugated with fluorophores, was utilized as a selective binder for adalimumab in the unprocessed cell culture supernatant. The nanofluidic device can separate the bound complex from unbound TNF-α and selectively concentrate the bound complex for high-sensitivity detection. Based on the fluorescence intensity from the concentrated bound complex, a fluorescence intensity versus titer curve can be generated, which was used to determine the titer of samples from filtered, unpurified Chinese hamster ovary cell cultures continuously. The system performed direct monitoring of IgG titers with nanomolar resolution and showed a good correlation with the biolayer interferometry assays. Furthermore, by variation of the concentration of the indicator (TNF-α), the dynamic range of the system can be tuned and further expanded.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call