Abstract

AbstractThe neutralization of NaOH with CO2 in a continuously operated airlift reactor with gas flow rates up to 10 NL min−1 and gas phase recycle was investigated. Neutralization experiments were performed at 25 °C and the amount of absorbed CO2, as well as the NaOH feed rate, were recorded. The reaction rate was calculated based on the two‐film theory and empirical equations for several parameters. The calculations of the volumetric mass transfer coefficient, the liquid phase circulation velocity, and the gas holdup were experimentally validated. The reaction rate and the process efficiency were modeled with a deviation of 5 %.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.