Abstract

Long discharges have been demonstrated by lower hybrid current-drive experiments on some tokamak devices. Discharges of longer than 1000 s are also planned for the International Thermonuclear Experimental Reactor (ITER) and Tokamak Physics Experiment (TPX) projects. In the case of long-time or steady-state operation, it is important to monitor the plasma parameters continuously and change the operational conditions during the discharge to maintain the plasma current. However, a conventional data acquisition and analysis system cannot follow these operations because it must show the results after each pulse. A new system that can continuously monitor and support steady-state operation is necessary. A new system is developed in which the signal flow is divided into branches, and one series of processing is made to switch alternately among the groups in every regular desired interval. An application of this system has been demonstrated on a 1-h discharge by TRIAM-1M. 9 refs., 6 figs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.