Abstract
This work advances the research on continuous mode-reversal frequency modulated accelerometers by characterizing in depth some of their nonidealities, proposing methods for their compensation, and exploiting a renovated sensor design that enables closed-loop compensation of shock and vibrations. The scale factor nonlinearity is first investigated and compensated through a cubic calibration term, yielding a 50% larger range for a 2.5-fold larger scale factor than in former implementations. Additionally, temperature effects on the zero-g offset are compensated by exploiting the value of the low-pass filtered resonance frequency, which yields a valuable information of the silicon sensor temperature. This enables reducing the zero-g-offset temperature dependence by a factor 5 over previous works on similar structures. Finally, a closed-loop compensation of the quality factor, implemented through additional driving electrodes in the structure, guarantees a 25-fold reduction on effects of shocks and vibrations exciting the acceleration-sensitive mode. [2022-0117]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.