Abstract

We have fabricated tunneling transit time (TUNNETT) diode with fundamental-mode oscillation in the frequency up to 706 GHz. Some inspection applications have been demonstrated using the feature of TUNNETT as predominant stability of the power and the frequency. The microanalysis of albumin bovine has been performed at pico-mole level. This method has been applied to detect the sugar levels in serum. A scanning millimeter-wave imaging has been demonstrated for an inspection of human liver tissue containing cancer cells with a special resolution at 0.3 mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.