Abstract

ABSTRACT A new technology for monitoring airborne heavy metals on aerosols and particulates based on spark-induced breakdown spectroscopy (SIBS) was evaluated at a joint U.S. Environmental Protection Agency (EPA)/U.S. Department of Energy test at the rotary kiln incinerator simulator (RKIS) facility at EPA/Research Triangle Park, NC, in September 1997. The instrument was configured to measure lead and chromium in a simulated combustion flue gas in real time and in situ at target levels of 15 and 75 u, g/dry standard cubic meters. Actual metal concentrations were measured during the tests using EPA Reference Method (RM) 29. The SIBS technology detected both lead and chromium at the low- and high-level concentrations. Additionally, the hardware performed without failure for more than 100 hr of operation and acquired data for 100% of the RM tests. The chromium data were well correlated with concentration increases resulting from duct operations and pressure fluctuations that are known to entrain dust.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.