Abstract

Four isotropically conducting adhesives were used to form lap joints between copper fingers which had been prepared with four surface metallizations (Cu, Au, Pd, and PdNi). A micromechanical tester was used to perform pull and fatigue tests on the 16 adhesive/finish combinations. The micro-ohm resistance change was measured during both the pull and fatigue tests. The similarities and differences between the mechanical strength, fatigue life, and resistance change for the 16 adhesive/finish combinations have been reported, and conclusions were made about relative motion between silver particles, and the fracture interfaces.