Abstract

Three-phase diode bridge rectifiers with a low source reactance cause considerable current harmonics in the AC supply, which may not meet the latest EMI regulations. At higher source reactance the bridge is more likely to operate in continuous conduction mode (CCM), leading to a reduction in harmonic current level. In the paper accurate analytical expressions are derived for the AC current harmonics, the input power and the power factor in CCM, which have been validated through numerical simulations and practical experiments. They can therefore be used with confidence for the design of power supplies with lower harmonic levels. Remedies are proposed to compensate for the drawbacks of CCM operation, using power factor correction capacitors and a single-switch inductor-less boost rectifier.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.