Abstract

In simulations of contaminated glove removal, 37% of health care personnel using their typical doffing technique contaminated their skin with a fluorescent solution. The frequency of contamination was significantly lower when the technique recommended by the Centers for Disease Control and Prevention was used versus not used (8 of 34, 24% vs 29 of 66, 44%). In simulations in which only the palm of the glove was contaminated, a modified doffing technique, to minimize the risk for contact with contaminated surfaces, reduced contamination of personnel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.