Abstract
A technique for removing surface contaminants from a sounding rocket spherical Langmuir probe is presented. Contamination layers present on probe surfaces can skew the collected data, resulting in the incorrect determination of plasma parameters. Despite following the usual probe cleaning techniques that are used prior to a launch, the probe surface can become coated with layers of adsorbed neutral gas in less than a second when exposed to atmosphere. The laboratory tests reported here show that by heating the probe from the interior using a small halogen lamp, adsorbed neutral particles can be removed from the probe surface, allowing accurate plasma parameter measurements to be made.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.