Abstract

Abstract A size exclusion liquid chromography (HPSEC) method using refractive index (RI) and photodiode array (PDA) detectors and a BASIC calculation program was developed for high molecular weight contaminant determination in the C15 linear paraffin-based cold rolling oil. Eight laboratory standards were analyzed to determine the new HPSEC/RI calibration factor for the C15 linear paraffin rolling oil. Three contaminants and thirteen standard solutions were evaluated to establish calibration curves. The HPSEC/RI/PDA method will quantitatively determine the concentrations of polyisobutylene-based hydrodynamic backup bearing lubricant, mist-applied extreme pressure gear oil for the workroll bearing and antiwear hydraulic oil in the cold rolling oil. Deviations for backup bearing lubricant, workroll bearing lubricant and hydraulic oil are approximately 3%, 4% and 7% of the contaminant concentration, respectively. The BASIC calculation program can assist operators in reducing calculation error and improving s...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.