Abstract

The ability of the CONTAIN code to predict the thermal hydraulics of five experiments performed in the NUPEC 1/4-scale model containment was assessed. These experiments simulated severe accident conditions in a nuclear power plant in which helium (as a nonflammable substitute for hydrogen) and steam were coinjected at different locations in the facility with and without the concurrent injection of water sprays in the dome. Helium concentrations, gas temperatures and pressures, and wall temperatures were predicted and compared with the data. The use of different flow solvers, nodalization schemes, and analysis methods for the treatment of water sprays was emphasized. As a result, a general procedure was suggested for lumped-parameter code analyses of problems in which the thermal hydraulics are dominated by water sprays.