Abstract

Acoustic emission (AE) signals were used to investigate the contact force occurring at the head/disk interface of a computer hard drive. The AE sensor was calibrated directly using the “ball drop method” and indirectly using system identification. For the indirect calibration, a high bandwidth laser Doppler vibrometer (LDV) was used. The transfer function was established from the harmonic response derived at different vibration modes and frequencies. A finite element method based transient response simulation of impact was used to estimate the velocity and stress response of the slider. In our experiments, contact forces were found to be in the range of 5–25 mN for nano sliders and 2–10 mN for pico sliders.