Abstract

The paper proposes an original method of determining of indicators of building fi re safety in regards to guaranteed resistance time for steel fi re-retardant SIN beams in conditions of standard fi re testing, evaluation of fi re-resistance design limits for steel fi re-retardant SIN beams during buildings design, construction and management, and cost saving during testing of steel structures for fi re-resistance. Operational benefi ts are obtained by non-destructive testing. Fire-resistance of fi re-retardant elements of SIN beam (corrugated wall, upper and lower beam fl anges) is evaluated by revealing of the most strong element of welded I beam.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.