A differential pressure gage for F2 was costructed. Two metal bellows were connected end to end and the net displacement of the connecting part was measured by a differential transformer. The output voltage per unit pressure difference was 1.7 mV/mmH2O. An apparatus for automatically controlling the outflow of batches of F2 gas was devised with the use of this gage, to replace the manual control practiced hitherto.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.