Abstract

This paper discusses the features and construction of a 1 6 - scale reinforced-concrete containment model that has been built at Sandia National Laboratories in Albuquerque, New Mexico. The model Light-Water-Reactor (LWR) containment building was designed and built to the American Society of Mechanical Engineers (ASME) code by United Engineers and Constructors, Inc. The containment model will be tested to failure to determine its response to static internal overpressurization. The results from testing the heavily instrumented containment will be used to assess the capability of analytical methods for predicting the performance of containments subject to severe accident loads as part of the US Nuclear Regulatory Commission's program on containment integrity. The scaled dimensions of the cylindrical wall and hemispherical dome are typical of a full-size containment. Features representative of a prototypical containment and included in the heavily reinforced model are equipment hatches, personnel airlocks, several small piping penetrations, and a thin steel liner attached to the concrete by headed studs.