Abstract
Two prototype position sensitive parallel plate avalanche counters (PPACs) have been fabricated at the Rare Isotope Science Project (RISP). Both detectors have active areas of 10 × 10 cm2 and utilize a stripped electrode structure, together with a delay line readout, to extract position information. Testing was conducted with an 241Am α source, and 2-dimensional position information was obtained. A position resolution of 0.55 mm full width at half maximum (FWHM), together with a position linearity of ±55 μm over a 67-mm detection range, were measured. A time resolution of 450 ps (FWHM) was also measured.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.