Abstract

Automated control systems badly need measurements of fast-changing non-stationary physical quantities in real time, or close to that. In this area, there is a separate group of tasks on measuring the non-stationary pressure in liquids and gases. This paper demonstrates that measuring the non-stationary pressure in real time, or close to that, represents a problem on restoring an input signal, which, in terms of mathematics, belongs to the class of ill-posed problems (according to J. Hadamard). We have derived a solution to the inverse problem of measurement that is based on a mathematical model for measuring transformation enabled by a pressure sensor. Based on this solution, we have constructed a measuring method, which implies the wavelet processing of the sensor's output signal. In this case, we suggest that such basic functions of wavelet transformation should be selected that are the modification of the pulse transition function of the sensor. This paper reports an experimental study into the feasibility of the developed method, based on the measurement of the simulated pressure pulse. A pressure pulse is simulated by dropping a ball of the calibrated mass onto the sensor's membrane. We have proposed a measurement scheme for determining the duration of touch between the ball and the membrane. Testing the accuracy of the method implies comparing the actual mass of the ball with that derived from the sensor's output signal. The proposed method has demonstrated high accuracy because the maximum relative error in determining the mass of the falling ball was only 0.65 %. The proposed method for measuring the non-stationary pressure could be used in control systems that require the high-speed dynamic correction of a measurement error. Specifically, these include control system in aerospace engineering, testing complexes, military technology, scientific research

Highlights

  • At present, numerous highly technological automated control systems face a pressing issue to measure the fast-changing non-stationary physical quantities in real time, or close to that

  • Measuring the non-stationary pressure in real time represents a problem on recovering an input signal, which, from the standpoint of mathematics, refers to the class of ill-posed problems

  • The work shows that the fundamental equation of measurement will not have a single solution if a Fourier image of the sensor’s transfer function is finite, or is converted to zero at certain points

Read more

Summary

Introduction

Numerous highly technological automated control systems face a pressing issue to measure the fast-changing non-stationary physical quantities in real time, or close to that. Among these tasks, there is a separate group of tasks on measuring the non-stationary mechanical magnitudes, namely the pressure of liquids or gases. There are methods to solve ill-posed problems [6, 7], or methods to adjust a dynamic measurement error [8, 9] These methods are not applicable to measuring in real time, or close to that, because they are associated with an unacceptably high time cost, or are not precise enough. It is relevant task to construct precise and high-speed real-time methods for measuring the non-stationary pressure

Literature review and problem statement
The aim and objectives of the study
Theoretical aspects of measurement method
Practical implementation and studying the measurement method
Membrane
Analysis of the constructed measurement method
Discussion of the method to measure the nonstationary pressure
Conclusions
Findings