Abstract
SPC with positive autocorrelation is well known to result in frequent false alarms if the autocorrelation is ignored. The autocorrelation is a nuisance and not a feature that merits modeling and understanding. This paper proposes exhaustive systematic sampling, which is similar to Bayesian thinning except no observations are dropped, to create a pooled variance estimator that can be used in Shewhart control charts with competitive performance. The expected value and variance are derived using quadratic forms that is nonparametric in the sense no distribution or time series model is assumed. Practical guidance for choosing the systematic sampling interval is offered to choose a value large enough to be approximately unbiased and not too big to inflate variance. The proposed control charts are compared to time series residual control charts in a simulation study that validates using the empirical reference distribution control limits to preserve stated in-control false alarm probability and demonstrates similar performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.