Abstract

IntroductionIn addition to patient characteristics, consideration of length of construct to number of anchored levels ratio and rod diameter should be a part of preoperative planning to minimize implant-related complications (IRCs). IRCs including rod breakage, anchor dislodgement, and pullout are among the most common adverse events in traditional growing rods (TGRs). The current study hypothesized that anchor type and configuration are associated with IRC. MethodsPatients with (1) age ≤10 years at surgery; (2) spine-based dual TGR; (3) minimum 2-year follow-up; and (4) available imaging. Cephalad and caudal foundations were grouped based on the number of instrumented levels and anchor type. All radiographs were reviewed. Based on the results, a “construct levels / anchored levels” (CL/AL) ratio was calculated, which is the number of levels spanned by instrumentation divided by the number of levels with bone-anchor fixation. Receiver operating characteristic curve was used to define the CL/AL threshold. Results274 patients divided into patients with complications (IRC+, n = 140) and without complications (IRC–, n = 134) groups. Mean follow-up was 6.3 years (2.1–18.0 years). No significant differences in age, gender, body mass index, ambulatory status, etiology, primary curve size, T1–S1 height, coronal and sagittal balance, and rod material were observed between the two groups. Comparative analysis showed that connector type, presence and location of crosslinks, number of levels instrumented, number and type of anchors, presence of pelvic fixation, and mirroring of cephalad and caudal foundations were not different. However, maximum kyphosis and rod diameter were significantly different. The CL/AL ratio threshold was 3.5. Multivariate analysis of kyphosis, rod diameter, and CL/AL ratio showed a significant association with IRC (p < .05). Discussion and ConclusionAlthough patient characteristics like kyphosis have been proven to be associated with instrumentation failure, it is a combination of characteristics that include rod diameter and CL/AL ratio that showed significant correlation with IRC. Validation of the CL/AL ratio is recommended.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.