Abstract

This paper considers the use of constrained minimum crest factor multisine signals as inputs for plant-friendly identification testing of chemical process systems. The methodology presented here effectively integrates operating restrictions, information-theoretic requirements, and state-of-the-art optimization techniques to design minimum crest factor multisine signals meeting important user-specified time and frequency domain properties. A series of optimization problem formulations relevant to problems in linear, nonlinear, and multivariable system identification are presented; these culminate with their application to the modeling of the Weischedel–McAvoy high-purity distillation column problem, a demanding nonlinear and highly interactive system. The effectiveness of these signals for modeling for control purposes and the ability to incorporate a priori nonlinear models in the signal design procedure are demonstrated in this distillation system case study.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.