Abstract

The raw strain data collected from Keretapi Tanah Melayu Berhad (KTMB) railway are in variable amplitude. This paper discovers how the variable amplitude data can be changed to the constant amplitude data. It is found that the raw strain data is not suitable for fatigue and strength testing on Prestressed Concrete Sleepers (PCS). Apart from that, the most suitable method in determining the numbers of cycles is Rainflow Cycle Counting Method. Through rainflow cycle counting method, the number of cycles is determined. The numbers of cycles are used to simplify the laboratory test such as fatigue and strength test for the PCS. The frequencies of dynamic loading test on the PCS are set based the numbers of cycles. The constant strain data are also converted into constant loading data using the relationship of stress-strain and loading-stress. Constant amplitude loading will again simplify the laboratory testing. The goal is to show that the designs used in PCS are appropriate based on current loading demand. Then, a comparison of constant amplitude data is made between different numbers of coaches and freight train. The maximum data from the comparison shows that the higher loadings are obtained from freight train.