Abstract
Diffusion-weighted imaging (DWI) has been used for the detection and characterization of liver tumors because it has excellent contrast resolution. DWI using short tau inversion recovery (STIR) can improve tumor-to-liver contrast after gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) administration that shortens the T1 relaxation of liver parenchyma. To quantitatively and qualitatively compare the conspicuity of malignant liver tumors on DWI after Gd-EOB-DTPA administration between STIR and chemical shift selective (CHESS) sequences. Single-institution retrospective study. Fifty-seven patients with histologically confirmed malignant liver tumors were evaluated. Low b-value DWIs with STIR and CHESS sequences 18-20 minutes after Gd-EOB-DTPA administration were acquired at 1.5T. Tumor contrast-to-noise ratio (CNR) and visual grade of tumor conspicuity on DWI between STIR and CHESS sequences were compared. Paired Student's t-test and the Wilcoxon signed rank-test were applied. P < 0.05 was considered statistically significant. The mean tumor CNR and visual grade of tumor conspicuity on DWI were significantly higher for STIR than for CHESS (both P < 0.001). Regardless of the presence of chronic liver disease, the mean CNR (normal liver 33.5 ± 19.8 vs. 15.7 ± 12.2, P < 0.001; chronic liver disease 19.6 ± 11.0 vs. 9.2 ± 7.8, P < 0.001) and the visual conspicuity grade (normal liver 3.36 ± 0.64 vs. 2.56 ± 0.77, P < 0.001; chronic liver disease 2.94 ± 0.80 vs. 2.25 ± 0.84, P = 0.001) were significantly higher for STIR than for CHESS. Mean CNR and the visual conspicuity grade were also significantly higher for STIR than for CHESS in patients with hepatocellular carcinomas (CNR 18.1 ± 10.5 vs. 8.8 ± 7.2, P < 0.001; visual grade 2.88 ± 0.83 vs. 2.22 ± 0.87, P = 0.001) or metastases (CNR 35.0 ± 19.3 vs. 16.2 ± 13.1, P < 0.001; visual grade 3.45 ± 0.51 vs. 2.59 ± 0.73, P < 0.001). DWI using STIR may be more helpful for depicting malignant liver tumors after Gd-EOB-DTPA administration compared with DWI using CHESS. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:565-573.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.