Abstract

A workshop to reappraise the previous IWGT recommendations for photogenotoxicity testing [E. Gocke, L. Muller, P.J. Guzzie, S. Brendler-Schwaab, S. Bulera, C.F. Chignell, L.M. Henderson, A. Jacobs, H. Murli, R.D. Snyder, N. Tanaka, Considerations on photochemical genotoxicity: report of the International Workshop on Genotoxicity Test Procedures working group, Environ. Mol. Mutagen., 35 (2000) 173–184] was recently held as part of the 5th International Workshop on Genotoxicity Testing (IWGT) meeting in Basel, Switzerland (August 17–19, 2009). An Expert Panel was convened from regulatory, academic and industrial scientists (with several members serving on the original panel) and chaired by Dr Peter Kasper (BfArM, Germany). The aim of the workshop was to review progress made in photo(geno)toxicity testing over the past decade; a period which saw the introduction of several regulatory photosafety guidances in particular in Europe and the USA. Based on current regulatory guidelines a substantial proportion of compounds trigger the requirements for photosafety testing. Moreover, there has been growing concern within industry about the performance of the in vitro photosafety tests in the “real world” of compound development. Therefore, the expert group reviewed the status of the current regulatory guidance's and the impact these have had on compound development in the context of the various triggers for photosafety testing. In addition, the performance of photogenotoxicity assays (old and new) was discussed, particularly in view of reports of pseudophotoclastogencity. The Expert Panel finished with an assessment of the positioning of photogenotoxicity testing within a photosafety testing strategy. The most significant conclusion made by the Expert Panel was that photogenotoxicity testing should no longer be recommended as part of the standard photosafety testing strategy. In addition, progress was made on the refinement of triggers for photosafety testing. For example, there was support for harmonisation of methods to determine the Molar Extinction Coefficient (MEC) and a consensus agreement that there should be no requirement for testing of compounds with a MEC < 1000 L mol −1 cm −1.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.