Abstract

The electrical and mechanical time constants of a moving-magnet-type linear DC motor (LDM) are required to have small values so as to realize a high-speed response LDM. Simplified expressions of the electrical and mechanical time constants of the LDM are derived using the permeance method. These constants are also computed using the finite element method (FEM) combined with the electric circuit equation. The measured electrical and mechanical time constants are 10.5 ms and 1.6 ms, respectively. The calculated values of the electrical time constant obtained by the permeance method and the FEM are 13.4 ms and 10.2 ms, respectively. The calculated values of the mechanical time constant obtained by the permeance method and the FEM are 1.6 ms and 1.5 ms, respectively. It is clarified that both methods are useful for calculating the electrical and mechanical time constants of the LDM.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.