Abstract

It is commonly believed that the tetrameric Adair constants for oxygen binding to human hemoglobin can be evaluated from a single oxygenation experiment at 'high' hemoglobin concentration without considering the consequence of the presence of alpha beta dimers. We present examples which demonstrate that this is a very dangerous assumption. Without a knowledge of the complete oxygenation-linked dimer-tetramer association reaction (alpha beta Xi----(alpha beta)2Xj), it is impossible to predict a priori how high of a hemoglobin concentration would be required to make this assumption. Furthermore, without a knowledge of the complete oxygenation-linked dimer-tetramer association reaction, it is impossible to predict a priori the direction and magnitude of the systematic errors which are induced by making this assumption.