Abstract

BackgroundThere is a significant variability in reported fetal fraction (FF), a common cause for no‐calls in cell‐free (cf)DNA based non‐invasive prenatal screening. We examine the effect of imprecision in FF measurement on the performance of cfDNA screening for Down syndrome, when low FF samples are classified as no‐calls.MethodsA model for the reported FF was constructed from the FF measurement precision and the underlying true FF. The model was used to predict singleton Down syndrome detection rates (DRs) for various FF cut‐offs and underlying discriminatory powers of the test.ResultsIncreasing the FF cut‐off led to slightly increased apparent DR, when no‐calls are excluded, and an associated larger decrease in effective DR, when no‐calls are included. These effects were smaller for tests with higher discriminatory power and larger as maternal weight increased.ConclusionsMost no‐calls due to a low reported FF have a true FF above the cut‐off. The discriminatory power of a test limits its effective DR and FF precision determines the tradeoff between apparent and effective DR when low FF is used to discard samples. Tests with high discriminatory power do not benefit from current FF measurements.