Abstract

Blood cultures (BCx) are the gold standard for diagnosing blood stream infections. However, contamination remains a challenge and can increase cost, hospital days, and unnecessary antibiotic use. National goals are to keep overall BCx contamination rates to ≤3%. Our healthcare system recently moved to a BCx system with better organism recovery, especially for gram-negative, fastidious, and anaerobic bacteria. The study objectives were to determine the benefits/consequences of implementing a more sensitive blood culture system, specifically on contamination rates. The electronic health record was queried for all BCx obtained within our tertiary-care health system from April 2015 to October 2016. Cultures were divided into those obtained 12 months before and six months after the new system was introduced. A positive BCx was defined as one with any growth. Contaminated BCx were defined as those showing coagulase-negative Staphylococcus, Corynebacterium, Bacillus, Micrococcus, or Propionibacterium acnes. Cultures with Staphylococcus aureus, Klebsiella pneumoniae, or Escherichia coli were said to contain a true pathogen. Results based on hospital location of blood drawing also were determined. A total of 20,978 blood cultures were included, 13,292 before and 7,686 after the new system was introduced. With the new system, positive BCx rates increased from 7.5% to 15.7% (p < 0.001). Contaminants increased from 2.3% to 5.4% (p < 0.001), and pathogens increased from 2.5% to 5.8% (p < 0.001). Contaminated BCx increased significantly in the surgical/trauma intensive care unit (STICU), emergency department (ED), and medical ICU (MICU), while pathogen BCx increased on the surgical floor, ED, and MICU. A new blood culture system resulted in significant increases in the rates of positive, contaminated, and pathogen BCx. After the new system, multiple hospital units had contamination rates >3%. These data suggest that a "better" BCx system may not be superior regarding overall infection rates. More research is needed to determine the impact of identifying more contaminants and pathogens with the new system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.